Accuracy Class OIML R60 C3 OIML R60 C4 OIML R60 C5
Output Sensitivity ( = FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) 500kg
Max. Number of Load Cell Intervals nLC 3000 4000 5000
Ratio of min. LC Verification Interval Y = Emax / vmin 10000 15000 20000
Combined Error %FS ≤± 0.0230 ≤± 0.0175 ≤± 0.0140
Creep Error (30 minutes) %FS ≤± 0.0167 ≤± 0.0125 ≤± 0.0100
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.020 ≤± 0.012 ≤± 0.009
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.0175 ≤± 0.0131 ≤± 0.010
Zero Balance %FS ≤± 2.0
Safe Overload %FS 150
Ultimate Overload %FS 200
Maximum Deflection mm 50kg -200kg: ~0.7-0.9 250kg -500kg: ~0.9-1.3
Eccentric Loading Error %Ld/cm ≤± 0.002
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 406 ± 6
Output Resistance Ω 350 ± 3.5
Insulation Resistance (50V) MΩ ≥5000
Compensated Temperature °C -10 ~ +40
Operating Temperature °C -35 ~ +65
Storage Temperature °C -40 ~ +70
Load Cell Weight kg ~0.6
Element Material Aluminium
Ingress Protection (acc. to EN 60529) IP65
Recommended Torque on Fixation Bolts Nm M8: 25